Autosave

Enterprise Feature

Autosave is only available in the enterprise edition with cibseven.webclient.modeler.enabled: true, from 3.0.0. See Enable / Disable. In the community edition every change is saved with the save button.

With autosave on, the modeler saves a diagram or a form by itself shortly after you change it, so a closed browser or a lost connection costs at most the last moments of work.

Switching Autosave On and Off

Autosave is off by default. The arrow beside the save button in the editor toolbar opens a menu with Autosave on and Autosave off. While autosave is on, the save button shows a check mark, and its tooltip says so.

The choice is kept in your browser and applies to every tab, for BPMN and DMN diagrams and for forms alike. Another browser, or another user of the same browser, keeps a choice of its own.

When It Saves

Two seconds after your last change, the modeler saves the model, the same way the save button does: the dot on its tab goes away, and the key checks of a manual save apply. Each further change starts the two seconds again, so a model is not saved in the middle of an edit.

Autosave works only on a model that has been saved before. A new model, or a newly imported one, has to be saved with the save button once; from then on autosave takes over.

Autosave does nothing for a model you may only look at, for example as a Viewer in a project, see Project Members.

What It Shows

An autosave gives no message of its own. Next to the snapshot button of the editor, the modeler shows how the last autosave went:

Message Meaning
Autosaved at time The model was saved at that time
Couldn’t autosave — locked by another user Another user is working on the model. Autosave never asks you to overwrite their work; save with the save button to decide
Autosave failed — your last changes are not saved The save did not succeed. Your changes are still in the editor; save them with the save button

Saving with the save button clears the message.

Autosave and Snapshots

Every autosave is a save, so every one records a snapshot, as a manual save does. With autosave on, a working session leaves many snapshots, and the retention job (cibseven.webclient.modeler.history.versionLimit, default 50) reaches older states sooner.